ENTRON Resistance Welding Control
Single Phase |
Single Phase Constant Current |Three Phase |
Seam Welder
|
Single Phase Controls
|
|
Model
EN1000 Microprocessor Based Single
Contactor Control with the Following Features:
|
|
|
· Spot Sequence
· Pulsation Sequence
· Up & Down Slope
· Quench & Temper
· Forge Delay
· Multiple Weld/Multiple
Current Sequence
· Preheat/Post Heat
· External Schedule Select
· Process & Error Outputs
· Seam Sequence
|
|

|
|
|

|
· 50 Unique Schedules
· Chained & Successive Modes
· Repeat & Non-Repeat
· Weld & Valve Control Relays
· 3 Valve Outputs
· Multiple Weld Programming
· Multiple Job Set-Ups
· Easily Programmed
· Program Only the Functions
Required
|
|
|
|
|

|
|
|
|
Single Phase Constant Current
|
Model EN1001 Microprocessor Based Single
Contactor Control with the Following Features:
|
| |
· Spot Sequence
· Pulsation Sequence
· Up & Down Slope
· Quench & Temper
· Forge Delay
· Multiple Weld/Multiple
Current Sequence
· Preheat/Post Heat
· External Schedule Select
· Process & Error Outputs
· Seam Sequence
|
|
 |
| |
 |
· 50 Unique Schedules
· Chained & Successive Modes
· Repeat & Non-Repeat
· Weld & Valve Control Relays
· 3 Valve Outputs
· Multiple Weld Programming
· Multiple Job Set-Ups
· Easily Programmed
· Program Only the Functions
Required
|
| |
· Primary and Secondary
Sensing
· Two Minute Set-Up Procedure
· No Transformer Tursnratio
Calculation Required
· Constant Current Program
Modes
Percent Current Steps
Secondary Current
Kiloamperes
Proportional to Maximum
Current
· Range: 1,000 to 50,000
Secondary Amperes
· Current Monitor with Hi/Lo
Limits
|
|
 |
|
Three Phase Controls
|
Model EN1003 Microprocessor Based Multiple Sequence
Three Phase DC Control with the Following Features:
|
| |
· 3 SCR Contactors
· Spot Sequence
· Pulsation Sequence
· Up & Down Slope
· Quench & Temper
· Forge Delay
· Multiple Weld/Multiple
Current Sequence
· Preheat/Post Heat
· External Schedule Select
· Seam Sequence
· Brazing
· Flash Welding
· Retraction
· Squeeze Delay
· Stepper
|
|
 |
|
Application
Flexiblity |
|
Transformers can be
connected in as Inside Delta, Outside Delta, or
"Y" configuration. |
| |
· 50 Unique Schedules
· Chained & Successive Modes
· Repeat & Non-Repeat
· Weld & Valve Control Relays
· 3 Valve Outputs
· Multiple Weld Programming
· Multiple Job Set-Ups
· Easily Programmed
· Program Only the Functions Required
|
|
|
Seam Welder Controls
Model EN1500 Microprocessor Based Seam Welding
Control Complete with the Following Features:
|
| |
· Seam Sequence
· Preheat/Postheat
· Up & Down Slope
· Continuous/Internittent
· Beat/Non-Beat Operation
· End of Sequence Output
· Hiearchial Iniation Structure
· 50 Unique Schedules
· Weld & Valve Control Relay
· 1 Value Output
· Multiple Job Set-Ups
· Easily Programmed
· Program Only the Functions
Required
· Spot/Roll Spot
|
|
 |
| |
Change Current "On
the Fly" (while welding) with Manual Current
Adjust Optional |
|
Model
EN1501 Microprocessor Based Constant Current
Seam Welding Control Includes the Same Features as
the EN1500 Plus the Following Additional Features:
|
| |
· Primary or Secondary Sensing
· Two Minute Set-Up Procedure
· No Transformer Turns Ratio
Calculation Required
· Constant Current Program
Modes
Percent Current Steps
Secondary Current
Kiloamperes
Proportional to Maximum
Current
· Range: 1,500 to 50,000
Secondary Amperes
· Current Monitor with Hi/Lo
Monitor
|
|
 |
|
Go to
entron.com for more information on
Entron welding controls.